fgd@twgdmall.com    +86-18914538460
Cont

Have any Questions?

+86-18914538460

DC High Voltage Test Usaged 120kv 5mA DC High Voltage Generator for Surge Arrester

DC High Voltage Test Usaged 120kv 5mA DC High Voltage Generator for Surge Arrester

This product is mainly used for the ignition and control of industrial equipment with the energy of liquefied petroleum gas, natural gas and coal gas.
Send Inquiry
Chat Now

Product Introduction

Our company strict management to ensure the quality of High Voltage Generator, lighter for candles, torch stun gun, from raw materials to finished products have a complete set of quality testing. Our company not only provides customers with corresponding products, but also provides professional technical guidance and communication according to customers' needs. We have gradually become the loyal partner of many well-known enterprises at home and abroad.

Product Introduction

This product is mainly used for the ignition and control of industrial equipment with the energy of liquefied petroleum gas, natural gas and coal gas.

 

Product Parameter (specification)

Product Name

220VAC Electric Pulse Sparker Igniter

Supply Voltage

220VAC 

Input Voltage

AC200V-240V

Pulse Ignition Distance

≥6mm

Pulse Discharge Frequency

50Hz

Output high Voltage pulsed

≥16KV

Ignition Time

20S

Again Ignition Time

20S

Discharge Energy

≥2MJ

Circuit Feedback

0-20uA

Size

134*74*42mm

 

Product feature and application

1.Electric ignition or switching control ignition.

2.Ignite the gas again automatically if the fire went out accidentally.

3.Automatic monitoring or photoelectric control. If the fire went out, it can give warning automatically.

4.If it failed to ignite the gas or the fire went out accidentally, it can cut off the gas supply immediately.

5.Technology of Single-chip and digital microcomputer.

6.lightning proof.

 Infrared gas burner igniter-1

 

Product Details

★Vibration: amplitude: 1.5; vibratory frequency: 10Hz; it was tested in the direction of X, Y, Z when it has vibrated for 30m.


★Strength of wire coupling: Along the direction perpendicular to the connection wire, the test was made when the wire has been exerted 20N dead load.


★Blow test: At the height of 1m, in the direction of X.Y.Z, the test is made when it has fallen off naturally on a board with a thickness of 30mm.


★Temperature:it is tested after 1hr when the temperature returned to the room temperature with at least 5 times of cycle. Each cycle is within 1.5 hr separately at the temperature of -30℃ and+90℃


★Humidity: It is tested according to GB2423-3 for 48 hours, then it  is tested again after the voltage rating  was put on the igniter. The voltage rating is 0.7 and 1.1 times respectively.


★Durance: At the 1.2 times voltage rating, 4mm discharge distance, it acts continuously for 300hr


★No-loac Test: Open the high pressure terminal, and then ignite for 10hr at the voltage rating ( the accumulated time is 10hr; the timeof switching on the fire is 5s, and the time of switching off is 5s--it is a cycle).  


★High-pressure short-circuit test: Connect the high-pressure terminal to the earth and let it work continuously

for 2hr at 1.1 times voltage rating; then return to the normal test. (The accumulated time is 2hr; the time of switching on the fire is 5s, and the time of switching off is 5s--it is a cycle).

 

Gas burner igniter


FAQ

 

Q:When can I get the quotation?

A:We usually quote within 12 hours after we get your inquiry. If you are very urgent to get the price, please tell us so that we will regard your inquiry priority.

 

Q:How long does the pulse igniter module work?

A: It can be fired continuously for several minutes.

 

Q: How about the package?

A: The pulse igniters are packaged in a standard custom made outer carton.

 

Q:Can the high voltage module be customized as our need, such as put on our logo?

A:Surely our can be customized as your need, put on your logo is also available.


We always pay attention to the quality of our employees and expect them to apply their outstanding character to the production of our DC High Voltage Test Usaged 120kv 5mA DC High Voltage Generator for Surge Arrester, in order to meet the requirements of excellent quality. We carry out innovation and research of new technology from our own technical needs. We have a wealth of market experience, a well-developed marketing network, long-term development goals, and have established a high-quality and efficient sales platform at home and abroad.

Hot Tags: 220vac infrared electric pulse sparker igniter, China, suppliers, manufacturers, factory, customized, wholesale, buy, for sale, DC 3 6V Boost Step Up Power Module, ozone generator 10g, High Voltage Ignition Coil for Gas Burner, electric shock torch, Power Surfboard Igniter, DC 3 6V 4 8V 40KV High Voltage Generator Power Supply Boost Step up Module

[[ProKeywords]]

Send Inquiry